Sufficient Saturated Steam Industrial Steam Boilers Low Nitrogen Combustion With Low Heat Loss In Smoke Exhaust
Product Details:
Place of Origin: | Henan, China |
Brand Name: | TAIGUO |
Certification: | CE、EAC、SGS |
Model Number: | SZS |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 |
---|---|
Price: | US $10000.00 |
Packaging Details: | Bulk, packaged |
Delivery Time: | 30 working days |
Payment Terms: | L/C, T/T |
Supply Ability: | 100set |
Detail Information |
|||
Product Name: | Industrial Steam Boilers | Steam Yield: | 6t/h-45t/h |
---|---|---|---|
Working Pressure: | 1.25、1.6Mpa | Fuel: | Oil And Gas |
Highlight: | Sufficient Saturated Steam Industrial Steam Boilers,Low Nitrogen Combustion Industrial Steam Boilers |
Product Description
Industrial Steam Boilers Sufficient Saturated Steam Output Low Nitrogen Combustion With Low Heat Loss In Smoke Exhaust
Product introduction:
SZS series double-barrel steam boiler adopts safe water circulation design: the steam boiler water circulation adopts natural circulation loop, the water circulation flow resistance is small, there will be no stagnation, backflow, free liquid level and other water cycle condition deterioration phenomenon, effectively prevent the occurrence of pipe explosion accidents. Boiler water circulation adopts forced circulation loop to ensure the safety of water circulation. Corrugated furnace: The combustion chamber adopts the whole corrugated furnace structure, which not only strengthens the disturbance of flue gas, but also increases the radiation heat transfer area; It not only increases the stiffness of the furnace, but also effectively weakens the expansion stress of the furnace. It not only enhances the heat transfer effect, but also promotes the combustion of fuel in the furnace.
Product advantage:
1, long life, sufficient output, high efficiency. Scientific product design, advanced processing technology, rigorous quality control, all the boiler equipment produced by our factory, the continuous operation life is up to more than 10 years. The radiant heating surface of the boiler is the whole corrugated furnace and the convection heating surface is threaded smoke pipe. The heating surface is large, the boiler's heat production output is sufficient, and the thermal efficiency is higher than 92%, which is higher than the national regulations.
2. Abundant fuel, energy saving and environmental protection. The boiler combustion chamber design is reasonable, fully adapt to the city gas, natural gas, light diesel, heavy oil and other fuels, fuel in the furnace micro-positive pressure combustion, combustion is complete, less flue gas pollutants, boiler flue gas blackness, smoke blackness, concentration, noise and other technical indicators are better than the national first-class regional standards
Technical parameter;
Model ltem |
SZS4 |
SZS6 |
SZS10 |
SZS15 |
SZ20 |
SZ25 |
SZS30 |
SZS35 |
SZS40 |
|
Rated evaporation (t/h) |
4 |
6 |
10 |
15 |
20 |
25 |
30 |
35 |
40 |
|
Rated working pressure (Mpa) |
1.25/ 1.6/2.5 |
|||||||||
Rate steam temperature (℃) |
194/204/226 |
|||||||||
Feed water temperature (℃) |
20 | 20 | 104/20 | 104/20 | 104/20 | 104/20 | 104/20 | 104/20 | 104/20 | |
heating area(m) |
Body | 90.22 | 125.6 | 205.56 | 216.84 | 271.5 | 285.24 | 392.34 | 457.7 | 523.12 |
Economizer | 35.8 | 63.4 | 132.2 | 283.6 | 411.2 | 504.8 | 471.2 | 549.7 | 628.2 | |
Condenser | 25.4 | 41.5 | 62.8 | 101.1 | 134.7 | 168.3 | 252.4 | 294.7 | 336.8 | |
Available Fuel | natural gas ,biogas ,coke gas ,light oil ,methanol ,biodiesel etc ,heavy oil | |||||||||
Fuel consumption |
Natural gas (Nm3/h) |
288 |
432 |
720 |
1080 |
1440 |
1800 |
2160 |
2525 |
2881 |
Light oil (kg/h) |
244 | 372 | 620 | 930 | 1240 | 1550 | 1860 | 2079 | 2373 | |
Thermal efficiency (%) | >98 | |||||||||
Weight biggest part of Transportation (t) | 25 | 32 | 40 | 45 | 50.6 | 60 | 68.2 | 77 | 85.5 | |
Overall dimension boiler assembied L×W×H( m ) | 5.76*4.1 0*3.70 | 7.84*3.4 0*3.40 | 8.00*43. 60*4.70 | 8.90*3.9 0*4.00 | 8.90*3.9 0*4.00 | 10.50*4. 12*4.15 | 10.50*4. 30*4.23 | 11.78*4. 40*4.35 |
12.82*4. 45*4.40
|
Product operation flow chart:
Q1: How can you get the best price quickly?
1.We need to know the boiler capacity, the fuel you plan to use and the steam pressure you need, and then we can confirm the boiler model.
2. Customer needs to provide us your name, email address and company name, and then we will send you price list immediately.And if you use whatsapp, skype or wechat, you can provide us your ID, it will be more convenient for our communication.
Q2:Why choose us?
1.40+ years of boiler manufacturing experience, 10 years of export experience.A grade boiler factory.
2.Free replacement of parts for one year, lifetime maintenance of the main engine, except for improper operation.
Q3: Details of electric control cabinet
Electric control cabinet adopts PLC touch screen, display in English. It shows working condition details of boiler, such as water temperature, water pressure, exhaust gas temperature, and over-pressure alarm, etc. In addition, the cabinet is used for set up the parameter, record and analyze the operation data, etc.
Q4:What is the using life of your boiler?
1.Normally the boiler is designed for 20 years life span, but with right operation and good maintenance,the boiler can be used for 20-25 years.